Gledhill Building Products are manufactured under an ISO 9001:2000 quality management system which is independently audited and accepted BSI. All our products meet or exceed industry standards and comply with Water Regulations and Building Regulations.
All cylinders are available with either a top or side entry immersion heater boss on request and can be manufactured to suit: 10m, 15m or 30m working heads. Compression fittings are supplied and fitted free if required.
SAP Assessment - Use the appropriate loss factor in the ‘foam’ column in Table 2 of the SAP. The insulation thickness will normally be 30mm unless the client has specified otherwise. The factor for 30mm is 0.013GJ/Year/Litre.
Corrosion protection - All fully pumped indirect cylinders or combination tanks can be supplied with Corrosion Resistant Technology (CRT). This prolongs the life of the cylinder in aggressive water areas. (The mains water must be supplied by the mains water board - water from bore holes etc are not covered.)
Sizes - Generally domestic cylinder production encompasses capacities up to 360 litres in diameters from 300mm to 500mm, heights up to 2000mm and with working heads up to 30 metres. These are not limitations however, and many units outside these parameters are supplied every month at the suggestion of the specifier or our own design team.
|